MULTIPLEX
MONITOR SPECIFICATION
Picture
and technical specification and dimensions.
The Multiplex Oil Mist Detection system
has been designed to monitor up to 12
engine or atmospheric detectors or a combination
of both.

POWER
SUPPLY
Nominal 110V or 230V 50/60Hz to be specified
at time of ordering
MAXIMUM
POWER CONSUMPTION 100W
MAXIMUM
SAMPLING CHANNELS 12
RESPONSE
TIME 500 milliseconds simultaneously on
all channels
SYSTEM
OUTPUTS - RELAYS
Main
Alarm: Normally energized with 2 sets
of change over contacts
Early warning alarm: normally energized
with 1 set of change over contacts
Engine slow down: Normally de-energized
with 2 sets of change over contacts
Fault alarm: Maximum contact voltage rating
- 110V 1A or 240V 5A resistive.
Datalogging outputs 4/20mA
WEIGHT
Central Multiplex monitor unit (CMU):
10Kg
SEALED
TO IP65 WHEN ALL CONNECTIONS ARE MADE
MAXIMUM
DISTANCE
Maximum distance between Detector Heads
and CMU is 100 metres.
For longer distances a larger conductor
size is required.
FUSE
ARRANGEMENTS
Bottom FS1 200-250V 400mA anti surge-
Main Monitor
Top FS2 200-250V 400mA anti surge- 24V
DC